Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : Kacise
Model Number : KS 18 series
Place of Origin : China (Mainland)
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram,paypal
Supply Ability : 2000 Pieces per Week
Delivery Time : 5-8 work day
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
MOQ : 10 pcs
Supply voltage : 4 ... 30 VDC
Impedance : 10 kOhm ± 20 %
FS output (Span) : Min. 1.5 / typ. 2.8 / max. 5.3 m
Offset : 0 ± 0.2 mV/V
Body material : Al2O3 96 %
Type : pressure sensor
4 ... 30 VDC ceramic water pressure sensor transducer Element
1. Product Description
Kacise monolithic pressure sensors are manufactured in large series and are in use in a range of applications in machinery production, the automotive industry, and ventilation and climate control equipment. The easy installation and calibration of the sensors simplifies the customer's production processes. The KS18 SERIES features a compact design, high media compatibility and excellent long-term stability.
2. Details
Techinical parameters
PRESSURE RANGE | LONG THERM STABILITY* | LINEARITY / HYSTERESIS | BURST PRESSURE | OVER-PRESSURE | VACUUM CAPABILITY |
(BAR) | (TYP./MAX.) (% FS) ** | (BAR) | (BAR) *** | (BAR) | |
2 (1.6 ... 2.5) | ± 0.15 | ± 0.15 / 0.4 | ≥ 5 | ≤ 3 | −0.6 |
5 (4 ... 6) | ± 0.15 | ± 0.15 / 0.4 | ≥1 5 | ≤ 7.5 | −0.8 |
10 | ± 0.1 | ± 0.15 / 0.4 | ≥3 5 | ≤ 15 | −1 |
20 (16 ... 25) | ± 0.1 | ± 0.15 / 0.4 | ≥ 60 | ≤ 30 | −1 |
50 (40 ... 60) | ± 0.1 | ± 0.15 / 0.4 | ≥ 150 | ≤ 75 | −1 |
100 | ± 0.1 | ± 0.2 / 0.5 | ≥ 250 | ≤ 150 | −1 |
200 (160 ... 250) | ± 0.1 | ± 0.2 / 0.5 | ≥ 450 | ≤ 300 | −1 |
400 | ± 0.15 | ± 0.3 / 0.6 | ≥ 700 | ≤ 550 | −1 |
600 | ± 0.15 | ± 0.3 / 0.6 | ≥ 900 | ≤ 720 | −1 |
3. Feature
● 1000 hours @ 150 °C | 50 million pressure cycles @ 125 °C, 10 – 90 % FS @ 2.5 Hz | 3 thermal shocks +130 °C /−20 °C 3 K/sec. | 50 thermal cycles +150 °C /−40 °C, 2 K/min.
● For indipendent linearity 10 points are measured and compared to an ideal straight line.For all measurements, DUT’s are mounted in kacise standard Housing.
● Over-Pressure indicates the maximum (short time < 1 s) operating pressure within no irreversible damage to the printed circuit are expected.
3. Typical Application
![]() |
Kacise High Precision Pressure Sensor Compact Design For Automotive Industry Images |