Brand Name : Kacise
Model Number : KCS501X
Place of Origin : shanxi xi'an
MOQ : 1
Price : 1
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 1000 Pieces per Week
Delivery Time : 5 work days
Packaging Details : each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage temperature : -20-80℃
Operating temperature : -20-60℃
Operating humidity : 0-90%RH
Work pressure : 0.8-1.2atm
Supply voltage : 5-5.5V
Maximum operating current : 120-150mA
Light source current : 60-70mA
Warm-up time : 120S
T90 : 20S
repeatability of ZERO : <±50ppm
repeatability of 50% FS : <±5% of the measured value
life span : 10 year
KCS501X Infrared CO2 Module
Table 1 Version history
version | date | description |
V1.0 | 2016-10-12 | V1.0 released |
V2.2 | 2018-03-06 | Adapt product attribute modifications |
Table of Contents
KCS501X is a gas detection module based on the principle of NDIR infrared absorption, suitable for detecting carbon dioxide concentration in gas environment at room temperature.
KCS501X adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. KCS501X has good selectivity, no oxygen dependence, and long life.
KCS501X has UART, IIC digital output, analog voltage output and PWM frequency output mode, which is convenient for customers to choose applications; The KCS501X provides zero calibration, sensitivity calibration, and clean air calibration commands, and provides customers with a manually calibrated MCDL pin to facilitate the relative zero calibration of the sensor module using outdoor free-flowing clean air. KCS501X adopts diffusion ventilation method, which has a fast diffusion speed.
KCS501X can be widely used in HVAC fresh air control, indoor air quality monitoring, agricultural and animal husbandry production process monitoring, can be installed in intelligent buildings, ventilation systems, robots, automobiles and other applications. It can also be applied to other confined spaces for air quality monitoring.
KCS501X diffuse exterior view
KCS501X pump suction exterior view
parameter | symbol | minimum | Typical values | maximum | unit | |
Storage temperature | Tstg | -20 | - | 80 | °C | |
Operating temperature | TA | -20 | 60 | °C | ||
Operating humidity | HA | 0 | 90 | % RH | ||
Work pressure | PA | 0.8 | 1.2 | atm | ||
Supply voltage | Vs | 5 | 5 | 5.5 | V | |
Maximum operating current | Imax | 120 | 150 | mA | ||
Light source current | Iavg | 60 | 70 | mA | ||
Warm-up time | twarm | 90 | 120 | 180 | Sec | |
T90 | diffusion | - | 20 | 40 | second | |
repeatability | zero | <±50 | ppm | |||
50% FS | - | <±5% of the measured value | - | |||
life span | 3 | 10 | 15 | year |
Unit: mm
Diffusion
Pump-suction type
The sensor is mounted with a positioning hole spacing of 44.5mand a mounting hole diameter of 2.8 mm
The wiring socket spacing is 2.54 m m
Note: SW400PV3.01, mounting aperture: 3.2mm
The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on
Do not use the sensor for a long time in an environment with a high density of dust
Please use the sensor within the range of the sensor's power supply
3) Sensor measurement accuracy such as SW400, 0-2000pp
Order information sheet | |||||
KCS501X | KCS501X CO2 concentration sensor | ||||
xxxx | The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm. | ||||
2000 | Range 200ppm (default). | ||||
10000 | Range 10000ppm | ||||
50000 | Range 50000ppm | ||||
encode | The reaction speed is divided into two types: fast and slow | ||||
S | Slow (default). | ||||
Q | fast | ||||
encode | Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering. | ||||
Custom | Confirm the baud rate before ordering | ||||
2400 | 2400bps baud rate | ||||
9600 | 9600bps baud rate | ||||
19200 | 19200bps baud rate | ||||
38400 | 38400bps baud rate (default) | ||||
encode | Serial port protocol | ||||
Modbus-RTU | Standard Modbus-RTU protocol (default). | ||||
Modbus-ASCII | Standard Modbus-ASCII protocol | ||||
Modbus-Self | Modbus private protocol | ||||
KCS501X | -2000 | -S | -38400 | -Modbus-RTU |
URL: www.kacise.com
Tel: +86-29-17719566736
Email: sales@kacise.com
Address: Tangyan South Road, Xi'an City, Shaanxi Province, China
Shorthand | Full name |
VOL | 1% VOL refers to 1% of the volume of a particular gas in air. |
PPM | 1PPM means that the volume of a specific gas in the air accounts for one millionth. |
O2 | Oxygen molecules |
LCD | LCD display |
RS485 | Asynchronous serial port 485 |
DC | direct current |
AC | Communication |
PVC | polyvinyl chloride |
![]() |